Technical specifications
Power supply | 110 – 240 Vac ±10 % 50/60 Hz |
Operation temperature | -10 ~ +40 °C |
Z-Wave operation range | Up to 40 m indoors |
Beeper | Max. 80 dB at 5 cm |
Colours | ±2% |
Operation temperature | 16 million |
Luminance | 1090 cd/m2 |
Standby/max. consumption | 0,5 W / 1,5 W |
Installation in boxes | Ø ≥ 60 mm / at least 2M |
Z-Wave Repeater | Yes |
Dimensions (WxHxD) (with packaging) | 93x90x45 mm / (149x136x53 mm) |
Weight (with glass frame) (with packaging) | 114 g / (230 g) |
Supported Z-Wave Frequencies
ORDERING CODE (MODEL NUMBER) | Z-WAVE FREQUENCY |
ZMNHQD1 | 868.4 MHz |
Configuration parameters
Parameter no. 1 – Digital input type
Defines the input type of device connected to digital input.
Values (size is 1-byte dec):
• Default value 1
• 0 – Push-button
• 1 – ON/OFF toggle switch
• 2 – motion sensor
• 3 – motion sensor with memory (turned off after certain amount of time defined in parameter 5)
Parameter no. 3 – Turning off alarming
Values (size is 1-byte dec):
• default value 1
• 0 – only by z-wave command (basic set, switch multilevel set, switch multilevel start/stop level change, sound switch play tone, sound switch configuration, switch color set, switch color start/stop level change, notification report idle)
• 1 – capacitive input or z-wave command (basic set, switch multilevel set, switch multilevel start/stop level change, sound switch play tone, sound switch configuration, switch color set, switch color start/stop level change, notification report idle)
Parameter no. 5 – Motion sensor memory timer
Defines the time after which the output triggered by motion sensor is turned off.
Values (size is 2-byte dec):
• default value 10
• 0 – 32534 = 0-32534 seconds after which the LED will be turned off.
• 32535 – never turns off
Parameter no. 10 – Auto on timer
Defines the time after which the device is turned to last known state.
Values (size is 2-byte dec):
• Default value 0
• 0 – disabled
• 30 – 32535 = 30 – 32535 seconds after which the device turns on
ⓘ NOTE: If the user is performing an inclusion/exclusion/factory reset of this device and this parameter is configured to a non-default value, a change of output state can occur. This will result in an interruption of the inclusion/exclusion/reset process.
Parameter no. 11 – Auto off timer
Defines the time after which the device is turned to last known state.
Values (size is 2-byte dec):
• Default value 0
• 0 – disabled
• 30 – 32535 = 30 – 32535 seconds after which the device turns off
ⓘ NOTE: If the user is performing an inclusion/exclusion/factory reset of this device and this parameter is configured to a non-default value, a change of output state can occur. This will result in an interruption of the inclusion/exclusion/reset process.
Parameter no. 30 – Restore state on power failure
Values (size is 1-byte dec):
• Default value 1
• 1 – enabled (the device will restore state on power failure)
• 0 – disabled (the device will not restore state on power failure and will remain off)
Parameter no. 50 – Beeper enable/disable
This parameter affects beeper function just in case when the device receives the NOTIFICATION_REPORT. If the user sends a SOUND_SWITCH_TONE_PLAY_SET (1), the buzzer still emits a serviceable tone.
Values (size is 1-byte dec):
• Default value 1
• 0 – disabled (the beeper is not active)
• 1 – enabled (the beeper is active)
Electrical diagram
BASIC CONNECTION
SMART LIGHT IN COMBINATION WITH A SWITCH
SMART LIGHT IN COMBINATION WITH A MOTION SENSOR
L | Live (line) wire |
I | Terminal for input (connected to switch, sensor, device, etc.) |
I | Terminal for input (connected to neutral) |
N | Neutral wire |