Power supply | 12 / 24V DC |
PWM output frequency | 488Hz |
Rated output power | 8A for single output channel,13A at max.(3,25A for R.G.B.W. single output channel is suggested) |
Max load (e.g. halogen bulbs) |
At 12V- 156W combined At 24V- 312W combined |
LED Indicator | Red/Green *1 |
Operation temperature | 0℃~40℃ (32 ~ 104°F) |
Distance | up to 30 m indoors (98 ft) |
Dimensions (WxHxD) | 40.5 x 32 x 14.5 mm / 1,60×1,26×0,57 in |
Package dimensions (W x H x D) | 74 x 43 x 86 mm / 2,91×1,69×3,39 in |
Weight | 17 g / 0.60oz |
Gross weight (packaging included) | 43 g / 1.52oz |
Electricity consumption | 12V: 0.48W; 24V: 0.72W |
For installation in boxes | Ø ≥ 60 mm (2,36 in) or 2M (78,74 in),
depth≥ 60 mm (2,36 in) |
Z-Wave Repeater | Yes |
*Warning: the Qubino RGBW dimmer operates at a low voltage (12VDC/24VDC). See the instructions in the manual. |
Supported Z-Wave Frequencies
ORDERING CODE (MODEL NUMBER) | Z-WAVE FREQUENCY |
ZMNHWD1 | 868.4 MHz |
ZMNHWD2 | 921.4 MHz |
ZMNHWD3 | 908.4 MHz |
ZMNHWD4 | 869,0 MHz |
ZMNHWD5 | 916,0 MHz |
ZMNHWD6 | 868,4 MHz |
ZMNHWD7 | 919,8 MHz |
ZMNHWD8 | 865,2 MHz |
ZMNHWD9 | 922,5 MHz |
ZMNHWDA | 919,7 – 921,7 – 923,7 MHz |
ZMNHWDB | 868,1 MHz |
ZMNHWDC | 868,1 MHz |
ZMNHWDD | 919,8 MHz |
ZMNHWDE | 920,9 MHz |
Configuration Parameters
Parameter no. 1 – Input IN1 configuration
Available configuration parameters (size is 1 Byte DEC)
-
Default value: = 4 (BRIGHTNESS mode – momentary switch type)
-
1 – NORMAL mode – momentary switch type
-
2 – NORMAL mode – toggle switch type
-
3 – NORMAL mode – toggle with memory switch type (exp. Motion sensor)
-
4 – BRIGHTNESS mode – momentary switch type
-
5 – BRIGHTNESS mode – toggle switch type
-
6 – BRIGHTNESS mode – toggle with memory switch type (exp. Motion sensor)
-
7 – RAINBOW mode – momentary switch type
-
8 – SCENE mode – momentary switch type
-
9 – SCENE mode – toggle switch type
-
10 – SCENE mode – toggle with memory switch type (exp. Motion sensor)
Parameter no. 2 – Input IN2 configuration
Available configuration parameters (size is 1 Byte DEC)
-
- Default value: = 7 (RAINBOW mode – momentary switch type)
-
1 – NORMAL mode – momentary switch type
-
2 – NORMAL mode – toggle switch type
-
3 – NORMAL mode – toggle with memory switch type (exp. Motion sensor)
-
4 – BRIGHTNESS mode – momentary switch type
-
5 – BRIGHTNESS mode – toggle switch type
-
6 – BRIGHTNESS mode – toggle with memory switch type (exp. Motion sensor)
-
7 – RAINBOW mode – momentary switch type
-
8 – SCENE mode – momentary switch type
-
9 – SCENE mode – toggle switch type
-
10 – SCENE mode – toggle with memory switch type (exp. Motion sensor)
Parameter no. 3 – Input IN3 configuration
Available configuration parameters (size is 1 Byte DEC)
-
Default value: = 8 (SCENE mode – momentary switch type)
-
1 – NORMAL mode – momentary switch type
-
2 – NORMAL mode – toggle switch type
-
3 – NORMAL mode – toggle with memory switch type (exp. Motion sensor)
-
4 – BRIGHTNESS mode – momentary switch type
-
5 – BRIGHTNESS mode – toggle switch type
-
6 – BRIGHTNESS mode – toggle with memory switch type (exp. Motion sensor)
-
7 – RAINBOW mode – momentary switch type
-
8 – SCENE mode – momentary switch type
-
9 – SCENE mode – toggle switch type
-
10 – SCENE mode – toggle with memory switch type (exp. Motion sensor)
Parameter no. 4 – Input IN4 configuration
Available configuration parameters (size is 1 Byte DEC)
-
Default value: = 1 (NORMAL mode – momentary switch type)
-
1 – NORMAL mode – momentary switch type
-
2 – NORMAL mode – toggle switch type
-
3 – NORMAL mode – toggle with memory switch type (exp. Motion sensor)
-
4 – BRIGHTNESS mode – momentary switch type
-
5 – BRIGHTNESS mode – toggle switch type
-
6 – BRIGHTNESS mode – toggle with memory switch type (exp. Motion sensor)
-
7 – RAINBOW mode – momentary switch type
-
8 – SCENE mode – momentary switch type
-
9 – SCENE mode – toggle switch type
-
10 – SCENE mode – toggle with memory switch type (exp. Motion sensor)
Parameter no. 5 – Auto Scene Mode Set
Available configuration parameters (size is 1 Byte DEC)
-
Default value 1
-
1 – Ocean (soft flowing between shades of blue colour)
-
2 – Lightning (fast flashing of white colour)
-
3 – Rainbow (flowing between colours of rainbow)
-
4 – Snow (flowing between shades of white and cyan colour)
-
5 – Romantic (soft flowing of the red colour)
-
6 – Party scene (random flashing between colours)
Parameter no. 6 – Auto Scene Mode – Duration between Colour change
This parameter is used to adjust time between 2 Colours in the Scene
Available configuration parameters (size is 2 Byte DEC)
-
Default value 3
-
1-127 – delay duration is 1 sec to 127 sec
-
1001-1127 – delay duration is from 1 min to 127 min. This parameter has no effect on Lighting and Party Scene.
Parameter no. 7 – Memorize device status at power cut
Device will be set to status memorized before power cut.
Available configuration parameters (size is 1 Byte DEC)
-
Default value 0
-
0 – device does not memorize its status at power cut. Load is disconnected
-
1 – device memorizes its status at the power cut. Load will be set to the status from before power cut
Parameter no. 8 – Automatic turning off output after set time
Output is turned automatically off after the time, set in this parameter.
Available configuration parameters (size is 2 Byte DEC)
-
Default value 0
-
0 – Auto OFF disabled
-
1 – 32536 = 1 second – 32536 seconds Auto OFF
Parameter no. 9 – Automatic turning on output after set time
Output is turned automatically on after the time, set in this parameter.
Available configuration parameters (size is 2 Byte DEC)
-
Default value 0
-
0 – Auto ON disabled
-
1 – 32536 = 1 second – 32536 seconds Auto ON
Parameter no. 10 – MAX dimming value
Available configuration parameters (size is 1 Byte DEC)
-
Default value 99
-
2-99 = 2 % – 99 %
Parameter no. 11 – MIN dimming value
Available configuration parameters (size is 1 Byte DEC)
-
Default value 1
-
1-98 = 1 % – 98 %
NOTE: The minimum level may not be higher than the MAX dimming value.
Parameter no. 12 – Dimming time (soft on/off)
Available configuration parameters (size is 1 Byte DEC)
-
Default value 10 = 1 s
-
5 – 25 = from 0.5 to 2.5 seconds
Parameter no. 13 – Dimming time when key pressed
Available configuration parameters (size is 1 Byte DEC)
-
Default value 3 = 3 s
-
1 – 127 = from 1 to 127 seconds
NOTE: Dimming time depends also on Min and Max dimming value.
Parameter no. 14 – 4 Dimmers mode
Available configuration parameters (size is 1 Byte DEC)
-
Default value: = 0 (4 dimmers mode disabled)
-
0 – Four dimmers mode disabled
-
1 – Four dimmers mode enabled – momentary switch type
-
2 – Four dimmers mode enabled – toggle switch type
-
3 – Four dimmers mode enabled – toggle with memory switch type
NOTE: If the parameter no. 14 is enabled, parameter no. 1,2,3,4 has no effect.
NOTE: After parameter change, first exclude device (without setting parameters to default value) and then re include the device.
Electrical diagram
12/24V | Input for 12VDC or 24VDC (+) |
GND | Ground (-) |
IN1 | Push button – Brightness control (in default configuration) |
IN2 | Push button – Rainbow mode (in default configuration) |
IN3 | Push button – Scene mode (in default configuration) |
IN4 | Push button – Normal mode (in default configuration) |
Red | Output for R wire of LED strip or bulb in 4 Dimmers mode |
Green | Output for G wire of LED strip or bulb in 4 Dimmers mode |
Blue | Output for B wire of LED strip or bulb in 4 Dimmers mode |
White | Output for W wire of LED strip or bulb in 4 Dimmers mode |
S | Service button (used to add or remove device from the Z-Wave network) |